作者:John Hodgson;
作者單位:Penn Refractories Ltd., Lye, Stourbridge, West Midlands, England
刊名:The Refractories Engineer
ISSN:1362-4547
出版年:2002-01-05
卷:0
期:november
起頁:14
止頁:17
分類號:TQ175
語種:英文
關鍵詞:
內容簡介Plant trial work has shown the following benefits from using the argon bubbler/weir and dam system. · increased tundish sequence lengths by 15 percent · reduced alumina flushes by 37 percent, (measured from stopper trace data) · reduced alumina in pore tube by 42 percent (measure by plant personnel) · increased alumina in tundish slag by up to 7 percent · reduced alumina in mould slag by up to 5 percent. Penn Refractories' argon bubbler, dam and weir are fitted as standard to all slab caster tundishes at a major steel plant. Plant evaluations have also shown that baffles have improved inclusion flotation on the bloom caster at Corus Teesside and Scunthorpe Works, this has led to a significant reduction in impurity levels and steel qualities.
所需耐材幣:0